Base station with prewired outputs: 12 analog and 64 digital available via CANopen interface, 4 MOSFET digital. Cabling with M12 circular connectors or 10-pin reduced plug or cable gland. Internal antenna.

Technical data

Power supply
8-30 VDC
Antenna
Internal antenna; External optional with 1 or 5 meters extension cord.
Max number of outputs
12 analog
64 digital + 4 mosfet digital outputs
Rated current of STOP / Safety outputs
SO_1 = 2 A (30 VDC)
SO_2 = 2 A (30 VDC)
Rated current of digital outputs
2 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061)
up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061)
up to PL d, cat. 3 / SIL 2
Protection degree
IP 66 (NEMA 4)
Operating and storage temperature
operating: (-25 °C) ÷ (+70 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Cabling
Customizable – possible solutions include M12 circular connector, 10-pin reduced plug, M12 connector (8+5pin), cable gland
Dimensions
144x162x63 mm
5.67×6.38×2.48 in
Weight
650 g
1.43 lb