ARX

Compare

Compact base station with prewired outputs: up to 8 analog (voltage) and 16 analog PWM (8 bi-directional axes), maximum 16 digital, also available via CANopen interface upon request. Direct wiring on the solenoid valves or with 32, 40, 50 or 72-pin plug. External antenna.

Technical data

Power supply
8-30 VDC
Antenna
External. Antenna extension 1 or 5 meter optional.
Max number of outputs
8 analog (voltage)
16 analog PWM (8 bi-directional axes)
16 digital, also available via CANopen interface
Rated current of STOP / Safety outputs
SO_1 = 2 A (30 VDC)
SO_2 = 2 A (30 VDC)
Rated current of proportional outputs
2 A (30 VDC) – PWM
10 mA (28 VDC) – voltage
Rated current of digital outputs
2 A (30 VDC)
Safety performance of the STOP function (EN ISO 13849-1 / EN IEC 62061)
up to PL e, cat. 4 / SIL 3
Safety category for the protection against unintended movements from standstill UMFS (EN ISO 13849-1 / EN IEC 62061)
up to PL d, cat. 3 / SIL 2
Protection degree
IP 66 (NEMA 4)
Operating and storage temperature
operating: (-25 °C) ÷ (+55 °C) / (-13 °F) ÷ (+158 °F)
storage: (-40 °C) ÷ (+85 °C) / (-40 °F) ÷ (+185 °F)
Cabling
Customizable – direct wiring on the solenoid valves; 32, 40, 50 or 72-pin plug
Dimensions
240x186x83 mm
9.45×7.32×3.27 in
Weight
1.2 kg
2.7 lb

Dynamic Series Product Catalogue

Download